TM70 Handheld Wireless Remote Control
2. Follow the Outputs Diagram supplied with the system to connect the
power supply and the receiver outputs on the relay board plug-in
terminals. The Output Diagram indicates the relationship between the
transmitter commands and the receiver outputs.
• The
STOP relays K15 and K16 are in series and must be connected to the
main contactor coil circuit.
• The
K2/START is activated once the Warning/START command is held
down.
• The
K1/SEC relay is a security relay. It is activated when certain commands
predefined as
Active—commands that give rise to movements—are
activated.
K16 K15
K12K2 K14 K13 K11K1 K10 K9 K7K8 K6
K5 K3K4
SI GNAL
POWER
HARDOK
ID
DATA
FUSE 1A
K1 4 K1
K12
STO
K2
K1
K1 1 K10 K9 K8 K
K
K3K4K
N230/ AC
+/ AC
PE
N115/ AC
-/DC
N48/ AC
Figure 7. Main Board Connections, Relays, and LEDs
3. Select the
appropriate voltage on the receiver.
4. Be certain to connect the
ground cable.
CAUTION
Use only fireproof cables for connections.