5.3 - STARTING
UP
Proceed with caution; the equipment may not be connected correctly which may lead
to unforeseeable movements on starting-up.
Once the receiver has been connected, disconnect the power supply to the motors, (for example,
by removing the fuses) and power on the receiver. First of all the LEDs will light on an instant to
test that all are all right, after this the receiver will enter into a ‘SCANNING’ mode and the following
LED’s will be lit in the receiver;
POWER (1): ON, indicates that the power supply is correct.
HARDOK (2): ON, indicates the absence of faults on the boards.
SIGNAL (3): OFF, in the case of the channels being signal free. Blinks ON when
there is a RF signal on the channels.
DATA (4): OFF, when there is not another TM70 system active in the area. Blinks
ON in the opposite
case.
ID (5): OFF
CAN_RUN (6): ON, Indicates that CAN communications with expansion boards are
OK.
CAN_ERR (7): OFF
ORDER (8): OFF
RELAY (9): OFF
Figure 5. Signalling LEDs in the
receiver.
1.- Label for crane identification.
Optional: LCD
Display.
2.- LED.
3.- Manoeuvre button.
4.- Contact key.
5.- Start button.
6.- STOP button.
7.- Option: Range Limitation.
Figure 6. Command and signalling elements in the
transmitter