68
TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
OUTPUT 1 (VO1)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Output 1 connector
Pin Name
Function
VPP1
Power of channel 1
GND1
Ground of channel 1
VO1
Analogue output of channel 1
VR1
Zero position signal signal to get through the output 1 when the relay is inactive
OUTPUT 2 (VO2)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Output 2 connector
Pin name
Function
VPP2
Power of channel 2
GND2
Ground of channel 2
VO2
Analogue output of channel 2
VR2
Zero position signal signal to get through the output 2 when the relay is inactive
ISP (PROGRAMACION IN CIRCUIT / IN SYSTEM)
The expansion has a connector to record In-System(eg. Microprocessor software update). This connector
has 10 pins:
ISP connector
Pin name
Function
ISP2
Input connected to the ground to place the microcontroller in recording mode
TX2
Not used
RX2
Receiving data signal
GND
Ground
RX1
Receiving data signal
TX1
Transmisión data signal
ISP
Not used
VCC
Power supply output at 3,3 V
MRNOT
Reset input, active when it is connected to ground
+VI
Power supply output at 12 V (not stabilized, can vary between 8 y 22 V)
Vista de página 70