TM70Bi.v1.1.doc (10/03) 12
Solid green
Transmitter transmitting normally. OPERATION mode.
Green pulses.
Transmitter ready for start-up. STAND BY mode.
Red slow flashing
Battery level low
Red fast flashing
EEPROM module is not plugged in.
Red double flashing
Transmitter cannot start up because a motion
command is present.
Solid red
Transmitter failure
RECEIVER
In OPERATION mode the 5 LED’s must be lit as has been previously described in
section 4.3 Starting. If this is condition exists, press the transmitter motion buttons and
observe the response of the output relays. If the response is normal, the problem is not
related to the remote control equipment and the installation must be evaluated. If any
of the relays are not activated, the problem is associated with the remote control
equipment. If this happens, observe the status of the LED’s:
LED
LIT
ON
OFF
SIGNAL
RF signal OK
RF signal detection in
SCANNING mode
The receiver is not
receiving RF signals
POWER
Power Supply OK
Power Supply not OK
HARDOK
Board OK
Slow: fault in the board
Fast: error in EEPROM
Fault in the board
ID
ID Code OK (1)
ID not recognised
DATA
Is receiving the correct
data from a TM70 (1)
Signal received is not
correct
(1): DATA and ID LED’s show a weak flashing when data and the ID code are received
correctly but the Start command has not yet been received. Once Start button is
pushed ON the DATA and ID LED’s will show the standard strong flashing.
Vista de página 12