TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
26
13.5 Pushbuttons and Console Box PDOs
Pushbuttons
The system is provided with 4-byte configured transmission PDO (information bytes).
1
st
byte
Object 6000.1
2
nd
byte
Object 6000.2
3
rd
byte
Object 6000.3
4
th
byte
Object 6000.4
Start1
Start2
Stop
0
0
0
0
0
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
M11
M12
M13
M14
M15
M16
M17
M18
M19
M20
A1
A2
0
0
Transmission default is event driven, sent each time there is a change on any input.
Console Box
The system is provided with 12-byte configured transmission PDO (information bytes). The 12
th
byte includes one bit (0 or 1) corresponding with the display status
Ready (0) Busy (1).
1
st
byte
Object
6000.1
2
nd
byte
Object
6000.2
3
rd
byte
Object
6000.3
4
th
byte
Object
6000.4
5
th
byte
Object
6000.5
6
th
byte
Object
6000.6
7
th
byte
Object
6000.7
Start1
Start2
Stop
0
0
0
0
0
I1
I2
I3
I4
I5
I6
I7
I8
I9
I10
I11
I12
I13
I14
I15
I16
I17
I18
I19
I20
I21
I22
I23
I24
I25
I26
I27
I28
I29
I30
I31
I32
I33
I34
I35
I36
I37
I38
I39
I40
I41
I42
I43
I44
I45
I46
I47
I48
8
TH
byte
Object
6000.3
9
th
byte
Object
6000.4
10
th
byte
Object
6000.5
11
th
byte
Object
6000.6
12
th
byte
Object
6000.7
I49
I50
I51
I52
I53
I54
I55
I56
I57
I58
I59
I60
I61
I62
I63
I64
I65
I66
I67
I68
I69
I70
I71
I72
I73
I74
I75
I76
I77
I78
I79
I80
0 or 1
PDO transmission default is event driven, sent each time there is a change on any input.