TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
52
16.6.3 LA70M Installation and Connections
Make sure the machine is switched OFF and the work area is clear
during assembly.
Disconnect the power supply from the crane/machine. Check to
make sure power is OFF.
Be sure to connect the Earth Ground cable.
Use only those cables supplied by the manufacturer for connections
between the Master and Slave (or expansion) modules.
1. Select a suitable place to install the infrared transmitter. Make sure that it is away for
anything that could cause intense electrical disturbances. Make sure that there are no
obstructions to light transmission from the module.
2. Connect the unit to the proper power supply.
3. Jumper the Master/Slave block as MASTER.
4. Select the code that is programmed in the EEPROM of the transmitter.
5. Make sure to cap the last expansion module port with the supplied cap.
Note: The maximum number of Expansion Modules for each Master Module is two (2).
Figure 30. LA70M and LA70M Expansion Network
LA70M AC / LA70M DC
LA70M EX
ID=3 (*)
AC/DC Power Supply
LA70M EX
CAP