19.0 IN0450P Option
19.1 Description
The IN045P card when connected to the LR70 03V analog input, allows frequency
measurement conversion of a pulse generator operating between 0-450Hz. The card supplies a
+ 12VDC output used to provide power to the sensor. As a frequency to voltage converter,
feedback from an anemometer providing a pulsed signal is displayed providing real-time wind
speed information.
Card Technical Specifications
Figure 35. IN0450P Specifications
Characteristic
Detail
Max. Resolution
8 bits
Input Frequency Range
0 450Hz
Operating Temperature Range
-20ºC @ +70ºC
Isolation
Galvanically isolated from main logic board (LR70)
Figure 36. IN0450P