TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
46
16.3 Installation
Before You Begin:
Follow all local codes and safety regulations.
Make sure the main electrical power to the machine is OFF.
Make sure the work area is free from hazards.
Make sure of a proper earth ground.
Use flame resistant cables for the connections.
1. Make sure the Operator and TM70 transmitter position is line-of-site with the
LA70 IR module installation site.
2. Take appropriate precautions to make sure the LA70 IR module installation site
is away from electrical noise sources and obstacles that could shield the infrared
signal.
3. Use the mounting bracket on top of the enclosure to mount the LA70 IR module.
Remember, the dimensions of the ellipse (Figure 24) will change if the LA70 IR
module is not positioned so that it is pointing straight down. A wider operational
area is created by adjusting the mounting angle.
4. Choose the correct power supply setting on the LA70 IR module and connect
power.
5. Make sure the Master/Slave selector jumper is in the Master position for the first
LA70 IR module. Refer to Figure 26 below for the jumper location.
6. Select the code programmed in the transmitter EEPROM.
Figure 25: LA70 Layout
The diagram below illustrates the proper wiring of additional LA70 IR modules. Note the
master/slave jumper is shown in the Slave position in slaves 1 & 2.
Shielded cable must be used for communication between LA70 IR modules.
Select Supply Voltage
Select Code
Select Mode
Master
Slave
Power
Supply
Communication
with other LA70