25.2.9 Troubleshooting
Table 44. Troubleshooting
ERROR 1
Hardware Not Detected
More than one joystick moves together
No output associated
More than two associated outputs (maximum 2
associated analog outputs per lever/joystick)
ERROR 2
Hardware Not Detected Expansion is not initialized (output associated absent)
Place Enable Jumper
Initialized expansion, Tele-Alignment jumper not
connected.
ERROR 3
Two Joystick Selected
When moving the analog paddle to adjust, more than
one axis/joystick outputs are selected.
Different Joystick
A different joystick than selected moved when the
Tele-Alignment menu starts.
ERROR 4
This Adjust Not Possible
If the expansion’s output relay only activates when
Cmin exceeded.
ERROR 5
This Adjust Not Possible Output relay is activated when link exist.
Put Joystick To Neutral If the adjustment is possible and any paddle moves.
GEN. ERROR
No Access To Memory No access to memory to update data.
Adjust Not Valid The expansion indicates invalid values.
Quest./Answ. Not Valid
Erroneous communication between RX and
expansions.
No Answer Of Expans. The expansion doesn’t answer; communication error.
Error Other error.
25.2.10 Menu 3.2 Reset Values
Restores all outputs that support Tele-Alignment to default values.
25.2.11 Menu 3.3 FORB CAL MEN
Used to disable or cancel an entry to the Tele-Alignment menu. User should use Recorder
and/or TM70Config if the entry needs to be re-activated.