Technical Assistance Services (01/08) 14
The industrial units, as always, are installed in the plant itself and work with the same
frequency. To avoid interference every user must, at all times, have a listing of the units owned
with their working frequencies and check to ensure that they do not have units working on the
same frequency.
The change of frequency must only be made when we are sure that there are two units in
an installation with the same frequency. It must be noted that if a unit breaks down, it is not
repaired by changing the frequency. Every frequency change must be communicated to the user in
order to register it in his listing of units.
4.3.- COPYING OF EP70 (PUSHBUTTON)
Get near the receiver
Turn the key to the
contact position and
push and extract the
stop button. The LED
indicator will light up a
moment in yellow and
will blink green and
then turn off.
Press the upper left
button to the second
speed (the LED blinks
red at the rhythm of two-
on, one-off) and then the
start button. Keep both
pressed. The LED blinks
red three times at the
rhythm of two-on, one-
off and then turns yellow
for a few seconds; we
will then stop pressing the
two buttons.
We are in programming
mode and the LED now
indicates the base
channel on which it is
working at that
moment. It will first
indicate the tens with
green flashes and and
then the units with red
flashes. Then the LED
will emit some bursts of
amber light and will
remain lit in amber.
The transmitter is in a
state of frequency
change. To do this,
we first push on the
upper left button as
many times as the
number of tens of the
new frequency and
on the upper right
button as many times
as the number of
units of the new
frequency.
The LED will then
indicate the new
frequency with the
green flashes (tens)
and red flashes (units)
and then the LED will
emit some bursts of
amber light; it then
sends the new
frequency to the
receive and and on
finishing, remains lit
in amber.
key
Stop
button
Upper
left
button
Start
button
Example: If the unit is on
channel 12 the LED will
flash green once and
twice in red. If we do not
wish to change the
frequency we can leave
the programming mode
by pushing the stop
button
NOTE: If the unit has a
frequency under 10, as
the value of tens is 0,
the LED will not blink
green and will only mark
the units..
Example: If we want to
programme channel
12 we will push the
upper left button once
and the right one twice.
NOTE: If we want to
programme a
frequency under 10,
as the value of tens is
0, we will only push the
upper right button to
mark the units.
If programming is not
correct, repeat
process.
If programming is
correct. Push stop
button and when
starting the equipment
will work with new
frequency.